End-to-end consulting for Tier III & Tier IV data centers, structured cabling, critical power systems, and smart access control — built to Uptime Institute, TIA-942, and BICSI standards.
From RFP through commissioning and as-built documentation — we cover every phase of the data center and ICT infrastructure lifecycle.
Full Tier III and Tier IV facility design — space layout, power distribution, cooling, cabling pathways, and rack placement. Uptime Institute certification support and design reviews at PDR and CDR milestones.
Copper and fiber infrastructure design for enterprise and data center environments — Cat6A, Cat7, Cat8, single-mode and multi-mode fiber, MPO/MTP, EOR and ToR architectures, and full Fluke DSX certification.
Generator sizing, dual-feed A/B power path design, UPS integration, and electrical redundancy validation. Full commissioning and load-bank testing for mission-critical facilities. Caterpillar platform expertise.
HID smart card readers integrated with Panduit G6 PDU handles for granular per-door permissions. Real-time security alerts via email and WhatsApp, full audit trail, and scheduled access reports.
Integration with Sunbird Power-IQ and leading DCIM platforms for rack inventory, power monitoring, environmental sensors, and unified operational visibility across your entire facility.
Vendor-neutral consulting across the full project lifecycle: RFP development, BOQ, technical specifications, design reviews, gap analysis, ATP and commissioning procedures, and as-built documentation.
Our profile sits at the intersection of ICT, facilities, and critical infrastructure — a niche typically occupied by senior data center architects and mission-critical engineering specialists.
Accredited and certified by the leading bodies in data center design, network infrastructure, and engineering software.
We engage at every phase — from the first concept sketch to final as-built sign-off — delivering auditable, standards-driven deliverables at each milestone.
Requirements capture, scope definition, RFP / SOW preparation, and vendor-neutral specification writing.
Preliminary Design Review — architecture selection, topology design, standards alignment, and stakeholder review.
Critical Design Review — detailed engineering, BOQ, rack elevations, cabling schedules, and procurement package.
Acceptance Test Procedures, Integrated Systems Testing, certification, and sign-off.
Final as-built documentation, handover package, and ongoing operational support.
Thank you — we'll get back to you shortly.
Our DC Access Control system collects the following information for operational purposes:
All data is stored locally on the customer's infrastructure. No data is transmitted to external servers except for notification delivery (email SMTP, WhatsApp via Twilio).
We use Twilio to deliver WhatsApp notifications. Twilio's privacy policy applies to messages sent through their platform. See twilio.com/legal/privacy.
Access logs are retained according to the customer's configuration. Card holder data is retained until manually removed by an administrator.
For privacy inquiries: Mickey.Ziv@adm.co.il